10 test pouches, with cards and desiccants
10 capillary droppers
1 bottle of assay buffer
1 package insert

Model No: VD076
Abbr.: EHR-LSH Ab
Assay Time: 5-10 minutes
Specimen: Dog's serum, plasma and whole blood specimen
Specification
Ehrlichia-Leishmania Antibody Combo Test
Intended Use: cassette to diagnose the presence of antibodies against Ehrlichia canis, Ehrlichia ewingii, Leishmania canis.
Principle: lateral flow immunochromatographic assay.
Specimen: Dog's serum, plasma and whole blood specimen
Materials provided:
10 test pouches, with cards and desiccants
10 capillary droppers
1 bottle of assay buffer
1 package insert
Special Features:
Simultaneous detection of EHR and LSH
One-step testing procedure
Accurate results
A. The Ehrlichia test of the Ehrlichia-Leishmania Antibody Combo Test showed the result below.
| Relative Sensitivity | 98.44% |
| Relative Specificity | 98.62% |
| Relative Accuracy | 98.55% |
B. The Leishmania test of the Ehrlichia-Leishmania Antibody Combo Test showed the result below.
| Relative Sensitivity | 98.97% |
| Relative Specificity | 97.89% |
| Relative Accuracy | 98.26% |

TEST PROCEDURE
Allow all materials, including specimen and test device, recover to 15-25℃ before running the assay.
Take out the test card from the foil pouch and place it horizontally.
Use the capillary dropper to place 1 drop (approx.10μL) of the prepared specimen into each sample hole "S" of the test card. Then drop 3 drops (approx. 90μL) of the assay buffer into each sample hole. Start the timer.
Interpret the result in 5-10 minutes. Result after 10 minutes is considered as invalid.

INTERPRETATION OF RESULTS
Positive (+): The presence of both "C" line and zone "T" line, no matter T line is clear or vague.
Negative (-): Only clear C line appear. No T line.
Invalid: No colored line appears in C zone. No matter if T line appears.
Order Information
| Product No. | Product Name | Storage Temperature | Package Unit |
| VD076 | Ehrlichia-Leishmania Antibody Combo Test | 2-30°C | 10 Tests/Kit |