Rabbit Pasteurella Antibody Test
Used for:Rabbit Pasteurella Antibody Test
Model No:VD120Q
Abbr.:PUM Ab
Assay Time:5-10 minutes
Specimen:serum
Description
The Rabbit Pasteurella Ab Test is a lateral flow immunochromatographic assay designed for detection of Pasteurella multocida antibodies (PMU Ab) in rabbit serum. It offers two options for result reading: visual judgment or semi-quantitative analysis with the FIC-Q100N Dry Immunoassay Analyzer (required only for Method 2).
Specification
Intended Use:detection of Pasteurella multocida antibodies
Principle: lateral flow immunochromatographic assay.
Specimen: Rabbit serum
Materials provided:
5 PMU Ab test cards
5 Disposable droppers
1 Instruction for use

Test Procedure
Test procedures of visual interpretation

Before use, all components must equilibrate to room temperature (15 - 25°C) for 10 minutes.
1. Remove the test card from the foil pouch and place it flat on a work surface.
2. Transfer 3 drops (using a disposable dropper) of the sample into the sample well.
3. Start the timer. Wait for 5 to 10 minutes to read the result.
Interpretation of visual interpretation results

-Positive (+): Both the Control (C) line and Test (T) line appear as magenta-colored lines in the testing window. Any faintly visible T line -should be considered positive when the C line is also present.
-Negative(-): The C line is visible, but the T line is not visible.
-Invalid: No line appears in the C zone.
Test procedures of instrumental interpretation (Standard Test)

1. Turn on the FIC-Q100N Dry Immunoassay Analyzer.
2. Use the analyzer's scanner to scan the QR code on the inner label of the box or the label of bag to import the calibration curve into the analyzer.
3. Remove the test card from the foil pouch.
4. Position the front of the card facing up, ensuring that the sample well is oriented towards the outside of the analyzer's test card slot.
5. Insert the card into the test card slot of the analyzer.
6. Use a pipette with a range of 10-100 μL to place 100 μL of the prepared sample into the sample well.
7. Push the test card to the farthest end of the test card slot.
8. Tap "Standard Test" on the screen to start the testing. Please refer to the analyzer's operation manual for detailed instructions.
Test procedures of instrumental interpretation (Quick Test)

1. Turn on the FIC-Q100N Dry Immunoassay Analyzer .
2. Use the analyzer's scanner to scan the QR code on the inner label of the box or the label of bag to import the calibration curve into the analyzer.
3. Remove the test card from the foil pouch.
4. Transfer 3 drops (using a disposable dropper) of the sample into the sample well.
5. Wait for 5-10 minutes, then push the test card to the farthest end of the test card slot.
6. Tap "Quick Test" on the screen to start the testing. Please refer to the analyzer's operation manual for detailed instructions
Order Information
| Product No. | Product Name | Storage Temperature | Package Unit |
| VD120Q | Rabbit Pasteurella Antibody Test | 2-30°C | 5 Tests/Box |