High sensitivity and Accuracy.

Felivet Immunodeficiency Virus Ab-Leukemia Virus Ag Duo-Test
Model No: VD186Q
Abbr.: FIV-FeLV
Assay Time: 5-10 minutes
Specimen: feline serum, plasma, or whole blood
Description
The Felivet Immunodeficiency Virus Ab-Leukemia Virus Ag Duo-Test enables the rapid differential diagnosis of these pathogens by detecting antibodies specific to feline immunodeficiency virus, and antigens of feline leukemia virus in feline serum, plasma, or whole blood. It offers two options for result reading: visual judgment or semi-quantitative analysis with the FIC-Q100N Dry Immunoassay
Analyzer.
Specification
Intended Use: rapid differential diagnosis of these pathogens by detecting antibodies specific to feline immunodeficiency virus, and antigens of feline leukemia virus.
Principle: lateral flow immunochromatographic assay.
Specimen: feline serum, plasma, or whole blood.
Materials provided:
10 FIV-FeLV test cards
10 Vials of assay buffer
10 Disposable droppers
10 Capillary droppers
1 Instruction for use
Special Features:

Test Procedure
Test procedures of visual interpretation

1. Remove the test card from the foil pouch and place it flat on a work surface.
2. Transfer 1 drop (using a capillary dropper) of the treated sample into the sample well.
3. Transfer 3 drops (using a disposable dropper) of the assay buffer into the sample well.
4. Start the timer. Wait for 10 minutes to read the result
Interpretation of visual interpretation results

-Positive (+):
Feline immunodeficiency virus positive, C line and I line appear.
Feline leukemia virus positive, C line and L line appear.
Feline immunodeficiency virus and Feline leukemia virus positive, C line, I line and L Line appear.
-Negative(-): The C line is visible, but the I and L line is not visible.
-Invalid: No line appears in the C zone.
Test procedures of instrumental interpretation (Standard Test)

1. Turn on the FIC-Q100N Dry Immunoassay Analyzer.
2. Use the analyzer's scanner to scan the QR code on the inner label of the box or the label of bag to import the calibration curve into the analyzer.
3. Remove the test card from the foil pouch.
4. Position the front of the card facing up, ensuring that the sample well is oriented towards the outside of the analyzer's test card slot.
5. Insert the card into the test card slot of the analyzer.
6. Use a pipette with a range of 2-20 μL to place 10 μL of the prepared sample into the sample well. Then, use a pipette with a range of 10-100 μL to place 90 μL of the assay buffer into the sample well.
7. Push the test card to the farthest end of the test card slot.
8. Tap "Standard Test" on the screen to start the testing. Please refer to the analyzer's operation manual for detailed instructions
Test procedures of instrumental interpretation (Quick Test)

1. Turn on the FIC-Q100N Dry Immunoassay Analyzer .
2. Use the analyzer's scanner to scan the QR code on the inner label of the box or the label of bag to import the calibration curve into the analyzer.
3. Remove the test card from the foil pouch.
4. Transfer 1 drop (using a capillary dropper) of the treated sample into the sample well.
5. Transfer 3 drops (using a disposable dropper) of the assay buffer into the sample well.
6. Wait for 10 minutes, then push the test card to the farthest end of the test card slot.
7. Tap "Quick Test" on the screen to start the testing. Please refer to the analyzer's operation manual for detailed instructions.
Order Information
| Product No. | Product Name | Storage Temperature | Package Unit |
| VD186Q | Felivet Immunodeficiency Virus Ab-Leukemia Virus Ag Duo-Test | 2-30°C | 10 Tests/Box |