Feline Immunodeficiency Virus Antibody-Feline Leukemia Virus Antigen-Feline Coronavirus Antibody Combo Test

Feline Immunodeficiency Virus Antibody-Feline Leukemia Virus Antigen-Feline Coronavirus Antibody Combo Test

Model No:VD110
Abbr.:FIV Ab-FeLV Ag-FCoV Ab
Assay Time: 5-10 minutes
Specimen: Serum, plasma, whole blood

Description

Specification

 

Feline Immunodeficiency Virus Antibody-Feline Leukemia Virus Antigen-Feline Coronavirus Antibody Combo Test

 

Intended Use: for the qualitative detection of feline immunodeficiency virus antibody (FIV Ab), feline leukemia virus antigen (FeLV Ag) and feline Coronavirus antibody (FCoV Ab).

Principle: lateral flow immunochromatographic assay.

Specimen: Serum, plasma, whole blood.

Materials provided:

10 test pouches, with cards and desiccants

10 vials of assay buffer for FIV Ab-FeLV Ag

1 bottle of assay buffer for FCoV Ab

20 disposable droppers

10 capillary droppers

1 package insert

Special Features:
1.Simultaneous detection of FIV,FeLV and FCoV.

2.One-step testing procedure.

3.Accurate results.

A.The Feline Immuno deficiency Virus Antibody test of the FIV Ab-FeLV Ag-FCoV Ab Combo Test showed the result below.

product-580-158

B.The Feline Leukemia Virus Antigen test of the FIV Ab-FeLV Ag-FCoV Ab Combo Test showed the result below.  

product-580-156

C.The Feline Corona virus test of the FIV Ab-FeLV Ag-FCoV Ab Combo Test showed the result below. 

product-583-158

FIV Ab-FeLV Ag-FCoV Ab

TEST PROCEDURE

FIV Ab-FeLV Ag

Allow all materials, including specimen and test device, recover to 15-25℃ before running the assay.

Take out the test card from the foil pouch and place it horizontally.

Collect 50μL of the prepared specimen into a vial of assay buffer and mix well. Then drop 3 drops (approx. 120μL) of the diluted sample into each sample hole "S" of the test card, respectfully corresponding to the windows FIV, FeLV. Start the timer.

Interpret the result in 5-10 minutes. Result after 10 minutes is considered as invalid.

 
  product-877-391

FCoV Ab

Allow all materials, including specimen and test device, recover to 15-25℃ before running the assay.

Take out the test device from the foil pouch and place it horizontally.

Using the capillary dropper to place 1 drop of the prepared specimen into the sample hole "S" of the test device. Then drop 3 drops of the assay buffer into the sample hole immediately.

 
  product-1398-645

Interpret the result in 5-10 minutes. Result after 10 minutes is considered as invalid.

INTERPRETATION OF RESULTS

Positive (+): The presence of both "C" line and zone "T" line, no matter T line is clear or vague.

Negative (-): Only clear C line appear. No T line.

Invalid: No colored line appears in C zone. No matter if T line appears.

 

Order Information

 

Product No. Product Name Storage Temperature Package UnitPackage Unit
VD110 Feline Immunodeficiency Virus Antibody-Feline Leukemia Virus Antigen-Feline Coronavirus Antibody Combo Test 2-30℃ 10 Tests/Kit

 

Hot Tags: feline immunodeficiency virus antibody-feline leukemia virus antigen-feline coronavirus antibody combo test, China feline immunodeficiency virus antibody-feline leukemia virus antigen-feline coronavirus antibody combo test suppliers, manufacturers, factory, Feline Fcov Ag Test, Feline Coronavirus Antigen FCoV Ag Test, Feline Giardia Ag Test Kit, Toxo Ab Test Kit, Fiv Ab Rapid Test, Fcov Ag Test Kit